Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hand Surg Eur Vol ; 32(5): 560-2, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17950223

RESUMO

Anatomical variations of peripheral nerves are important and can help explain otherwise incomprehensible clinical findings. A study of 26 right and 18 left formalin-preserved upper limbs identified the fact that the musculocutaneous nerve is subject to considerable anatomical variation, including communication with the median nerve. A study of its branching pattern made us aware of why debility after trauma to the lateral aspect of the upper arm may be more than expected, and this study considers the clinical and surgical importance of these variations of the musculocutaneous nerve.


Assuntos
Braço/inervação , Nervo Musculocutâneo/anatomia & histologia , Humanos , Nervo Mediano/anatomia & histologia , Músculo Esquelético/inervação , Valores de Referência
2.
J Pharm Sci ; 74(1): 11-5, 1985 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-3981409

RESUMO

This paper describes the utility of the dynamic measurement of the angle of repose for pharmaceutical systems, using a variable rotating cylinder to quantify powder flow. The dynamic angle of repose of sodium chloride powder sieve fractions was evaluated using a variable rotating cylinder. The relationship between the static and the dynamic angle of repose is discussed. The dynamic angle of repose of six lots of a multivitamin preparation were compared for inter- and intralot variation. In both cases, no significant differences (p greater than 0.05) were observed. In the multivitamin formulation, lubricants at lower concentration levels did not show a significant effect (p greater than 0.05) on the dynamic angle of repose when compared with flow rates. The effect of different hopper sizes and geometry has been evaluated using the recording powder flowmeter. The results indicate that although different hoppers affect the quantitative nature of the results, the same general trends are apparent. Thus, it appears possible to use a recording powder flowmeter with small quantities of material to predict the effect of formulation and processing variables on the flow of production scale quantities. This paper does not describe a comprehensive evaluation of the pharmaceutical utility of measuring the dynamic angle of repose. However, the results discussed are not encouraging and suggest that the recording powder flowmeter is more sensitive to the effects of formulation and production variables on powder flow.


Assuntos
Pós , Química Farmacêutica , Tamanho da Partícula , Cloreto de Sódio , Ácidos Esteáricos , Tecnologia Farmacêutica , Vitaminas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...